The vent damper date code is located on a sticker under the motor assembly cap on the plastic base. Field formerly effikal vent damper motor rvgp ks.
A O Smith 120 Trough 500 Instruction Manual Manualzz
Effikal rvgp ksf wiring diagram. Rvgp pc 7bkf and it has a switch on the back of motor housing. Test for 24vac between black and orange on damper pc. Field formerly effikal vent damper wiring harness rvgp ks. If it has a reset on it push it and it just might reset the damper. Maintenance procedures in addition the maintenance and care of the boiler designated on page 3 and explained on the following pages must be performed to assure maximum boiler. Field controls 46491600 gma pl vent damper motor assembly plastic base.
Opened for pics your motor is new boxed. There is an automatic. When equipped with effikal vent damper model rvgp place service switch in hold damper open position. This is the only motor made for effikal vent dampers. It allows you to replace a defective motor without replacing an entire unit. Device must be installed by a qualified installer in compliance with local codes or the national fuel gas code ansi z2231 nfpa 54 or cancga b149 and the national electric code ansi c1 nfpa 70.
Checking and adjusting warning. Wiring diagram 118119 series controls. Field controls ovd 7 7 automatic oil vent damper 24v 46561707. Effikal rvgp ksf series flue damper troubleshooting guide see figure on front page of this insert sheet important. Effikal rvgp ksf series flue damper troubleshooting guide. Wiring errors can cause improper and dangerous operation.
Failure to follow this warning could result in explosion fire personal injury or death. Turn off all electrical power to the appliance. Follow the wiring from the damper and you should find it. This will save half the cost of replacing the entire assembly. 2 servicing should only be performed by a qualified service technician introduction this service handbook covers the water heater model and series numbers listed on. Keep boiler area clean and free from combustible materials gasoline and other flammable vapors and liquids.
This fits all size rvgp ks vent dampers use your existing assembly wiring harness or universal harness. Serial numbers are located on a label on the side of the dampers cap. If all steps have been tried and damper problems persists contact state water heaters 800 365 8170. Field controls 46491600 vent damper motor assembly plastic base this field controls replacement motor with plastic base takes only a few minutes to install. All sizes and models of the rvgp pc have the same motor assembly with black effikal caps and black plastic bases. Damper must be open before combustion takes place.
It goes without saying its not safe to let kids play with any boiler controls or the thermostat. When servicing controls all wires must be labeled prior to disconnection. Field formerly effikal vent damper 46487001 5 inch. 4950 shipping. Mine is a effikal model no. 16750 shipping.