Alltrax fn1 user controls. Download npx mini manual.
The Alltrax Sr48600 New Controller The Electric
Alltrax axe controller wiring diagram. Not all controllers use the a2 terminal used for plug braking. I even understood that. Alltrax fn1 user controls. Just a little concerned that the alltrax wiring diagram would be so far off or my precedent is a one off wiring situation on its on. This diagram is also shown on the npx mini manual. Alltrax toolkit can be used to set the range of these parameters to suite your needs.
By the way if youre looking for that wiring diagram the link is here. Any programming changes done in the vehicle should be performed with the vehicle safely disabled. Fn 1 provides interactive speed acceleration control for mild street to wild performance. Alltrax sr controller throttle wiring diagram doc110 045 cdwg sr throtle wiring page 1 2 dia. Plum quick motors 10590 tillman steen rd. If not bolt the two wires together insulate with tape or heat shrink then secure in safe location.
An example of the inputs and outputs are shown. The controller will power up via the usb cable so no external power supplies are needed. Product bulletin 05 e z go txt 48v cart and alltrax controllers revision a 8172010. The axe controller must be powered up before the controller pro program will have any effect. An example of the inputs and outputs are shown. Bench programmingpowering axedcx controllers doc100 033 adwg controller program diagrampdf.
Each unit reduces thousands of gas emissions each year. Alltrax axe to pm motor. Click on the image to enlarge. Alltrax srxct log file instructions alltrax srxct log file instructions. The sr has one user input called a personality switch. Works with all of our brushed motors like the me0909 me0708 me0709 and me1003 1004 36 48 72v models all work as low as 12v input 300 400 500 600 amps.
Fort mill sc 29707. Alltrax controller wiring diagram. Each car may use a particular connector. Speed and acceleration can be linked or separated using alltrax toolkit software setup. Visit documentation page. The newer controllers the spm and sr families of seriespm controllers wont have this issue as the current limit was designed to handle these inductive spikes and ignore them.
This diagram is very generic example please see the documentation page for the many various configurations this product can be used in. Over 200000 alltrax electric motor controllers have shipped. Click on the image to enlarge. Alltrax xctnctsr and spm controllers can be programmed on your bench using a usb printer cable and our free alltrax toolkit software. 8 of 14 6.