This should open the pressure switch contacts and stop burner operation. A power venter uses a motorized blower to vent the products of combustion.
Interactive Diy Solar Wiring Diagrams For Campers Van S
Field power venter wiring diagram. If wmo 1 switch is installed allow vent system to cool. See the chart below to select the proper kit for your application. Cas 4mv ck 81 chimney vent single 750mv gas appliance wiring diagram. Fields power venter wiring diagram field controls 46457800 user manual fields power venter wiring diagram wiring diagram is a simplified welcome pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes and the gift and signal associates along with the devices. The wiring should be protected by an over current circuit device rated at 15 amperes.
Check ground circuit to make certain that the unit has been properly grounded. Installation manual and wiring diagrams for models swg ii 5 swg ii 6 aga and swg 8 sidewall power venter kits. Search by combustion air treatment or ventilation. May require optional delay oil valve for simultaneous burner operation. Disconnect the vent pipe between the venter inlet and the appliance outlet. Search the field controls wring diagram library for all wiring disgrams on field controls products.
Block the vent pipe with a noncombustible material. Control kits can also control the operation of field draft inducers. Power venting or sidewall vent is more economical and safer than a chimney vent. 1 swgii 4hd sidewall power venter. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. The combovent mounts on the outside of the building and pulls the combustion gases from the appliance through the outside wall utilizing 100 negative pressure.
Single wall vent pipe refer to diagram b may be used to join the appliance to the power venter. Combo vent is the safest most efficient power venter available today the combovent cv combines the motor blower and vent hood in one complete easy to install unit. Swg replacement motor kit instruction manual. Connecting power venter to appliance figure 3 figure 4 diagram a 3. Wiring diagram for model cas 4mv power vent single 750mv gas appliance combustion air system. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
Field controls ck 63 venterburner control system for oil systems control kits ck control the operation of swgcv power venters. Mount the power venter through the wall keeping the outer pipe centered in the hole. While system is operating disconnect power to the venter motor. Swg 4g items included in kit. This equipment is designed to. Wiring instructions wire the venter motor and controls in accordance with the national electrical code manufacturers recommendations andor applicable local codes.
Sidewall power venting kit model. After determining the location of the venting system termination point see diagram a cut a square hole through the wall 1 larger than the outer pipe diameter of the power venter.